Descrizione di prodotto dettagliata
Gamma massima: 200A~1200A Tensione: 5
Sensibilità: G=2000/IP Uscita zero: 2,5
Consumo corrente: 13 Resistenza di carico: 10
Capacità del carico: 1 Resistenza interna dell'uscita: 10
Evidenziare:

5V Current Transducers

,

1200A Current Transducers

NACA.XXXM-S5 / SP2VA Current Transducers

Product Details

product manual

NACA XXXM-S5/SP2VA series current sensors are suitable for accurate measurement of AC, DC, and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.
 

Performance requirements
parameter name symbol unit parameter condition
Minimum Typical value Max
Electrical parameters
Maximum range IPN1 A 200A~1200A For more details, please contact CRRC
voltage UC V 4.75 5 5.25  
Operating temperature TA °C -40   125  
Output voltage (analog) Vout V Vout=(Uc/5)·(V0+G·Ip)  
Sensitivity G mV/A G=2000/IP @UC=5V
Zero output VO V   2.5    
Current consumption IC mA   13 15 @ UC=5V,No load on Vout
Load Resistance RL 10      
Load capacitance CL nF   1 10  
Output internal resistance ROUT Ω     10 DC
Performance parameter
Sensitivity error εG %   ±1   @TA=25℃,@UC=5V,IP≤900A
  ±2.25   @TA=25℃,@UC=5V,IP>900A
  ±3.25   @-40℃<TA<125℃,@UC=5V
Electrical zero offset FLY mV   ±3    
Magnetic zero offset FROM mV   ±2    
Zero output error Delete %   ±0.5   @TA=25℃,@UC=5V
  ±0.9   @-40℃<TA<125℃,@UC=5V
Proportional error .R %   ±0.5    
Linearity error εL %   ±0.5   Of full range
Response time tr μs   4 7  
bandwidth BW kHz 40     @ -3dB
Phase difference ∆φ ° -4     @DC to 1kHz

 

Dimensions
Series size
1200A 5V Current Transducers For AC Current Accurate Measurement 01200A 5V Current Transducers For AC Current Accurate Measurement 1

 

Mechanical parameters Remarks
● Plastic case PA 66 GF 25
● Magnetic core FeSi wound core
● Mass 50g

1200A 5V Current Transducers For AC Current Accurate Measurement 2

● VOUT>VO when IP flows in the positive direction (see arrow on drawing)

 

 

Procurement information

 

1. Products can be customized according to your needs. You are welcome to provide physical samples or detailed process drawings to design, produce and process.

 

2. If there is no special requirement, our company will assign logistics distribution and deliver the goods to customer factory

 

3. Payment method: delivery after payment, which can be negotiated according to the specific order quantity.

 

4. The response time of the number of customers should not exceed 8 working hours.

 

5. Emergency on-site service time shall not exceed 24 hours.

 